How to Import Transformers into Vietnam: HS Code, Duties and Energy Labels

Importing a transformer into Vietnam starts with the HS code: transformers fall under heading 8504, split into liquid dielectric and other types and by rated power (kVA). No import license is needed, but three-phase distribution transformers from 25 kVA to 2,500 kVA (including dry-type) must meet minimum energy efficiency and carry an energy label.
This guide helps you choose the code, look up the duty (MFN from 5% to 25% on common codes, VAT 10%) and follow the customs declaration steps. The key point: for distribution transformers, get a factory efficiency test report and check it against TCVN 8525:2015 before you pay.
SUMMARY: IMPORTING TRANSFORMERS INTO VIETNAM
- HS code: Heading 8504; liquid dielectric at 8504.21 and 8504.22, other types (including dry-type) at 8504.31 to 8504.34.
- Import duty: MFN duty on common codes is 5% to 25%; VAT for these codes is 10%.
- License: No import license is needed.
- Energy label: Three-phase distribution transformers from 25 kVA to 2,500 kVA must meet minimum efficiency and carry an energy label.
- Preferential C/O: A Form D C/O brings the codes in the table to 0%; a Form E C/O brings most codes to 0%.

HS codes for transformers
Heading 8504 is titled “Electrical transformers (power transformers and instrument transformers), static converters (for example, rectifiers) and inductors”. Liquid dielectric transformers fall under 8504.21 (up to 650 kVA) and 8504.22 (over 650 kVA up to 10,000 kVA).
Other transformers, including dry-type, fall under 8504.31 (up to 1 kVA), 8504.32 (over 1 kVA up to 16 kVA), 8504.33 (over 16 kVA up to 500 kVA) and 8504.34 (over 500 kVA).
| HS code | Description |
|---|---|
| 8504.21.99 | Liquid dielectric transformers, rated power not exceeding 650 kVA, other |
| 8504.22.11 | Liquid dielectric transformers over 650 kVA up to 10,000 kVA, step voltage regulators, high-voltage side of 66 kV or more |
| 8504.31.19 | Other transformers not exceeding 1 kVA, instrument transformers, other |
| 8504.32.19 | Other transformers over 1 kVA up to 16 kVA, instrument transformers not exceeding 5 kVA, other |
| 8504.33.19 | Other transformers over 16 kVA up to 500 kVA, high-voltage side of 66 kV or more, other |
| 8504.34.11 | Other transformers over 10,000 kVA up to 15,000 kVA, high-voltage side of 66 kV or more, adaptive transformers |
| 8504.34.12 | Same subheading as above: explosion-proof dry-type transformers |
The right code depends on the dielectric type, rated power, high-side voltage and function (power transformer, instrument transformer, current transformer, voltage regulator). For example, a 2,500 kVA oil-immersed unit falls under 8504.22, while a dry-type unit of the same rating falls under 8504.34.
Current transformers and low-power instrument transformers usually fall under 8504.31. Enclosures and parts imported separately are classified as parts, not as a complete transformer. The declarant is responsible for the code chosen, so the catalogue and nameplate should show all of these specifications.
Import duty and VAT
Duty rates follow the Preferential Import Tariff issued with Decree 26/2023/ND-CP and its amendments. Code lookup results on 10/11/2026:
| HS code | MFN | ACFTA (Form E C/O) | ATIGA (Form D C/O) | AKFTA | VAT |
|---|---|---|---|---|---|
| 8504.21.99 | 5% | 0% | 0% | 5% | 10% |
| 8504.22.11 | 25% | 0% | 0% | 5% | 10% |
| 8504.31.19 | 20% | 5% | 0% | 5% | 10% |
| 8504.32.19 | 10% | 0% | 0% | 5% | 10% |
| 8504.33.19 | 10% | 5% | 0% | 24% | 10% |
| 8504.34.11 | 10% | 0% | 0% | 5% | 10% |
All the codes in the table are at 0% under CPTPP and EVFTA. For 8504.33.19, the AKFTA rate is higher than MFN, so a Form AK C/O does not reduce the duty.
The lookup results for the 8504 codes above show VAT of 10%, not the 8% reduction that applies until 31/12/2026 under Decree 174/2025/ND-CP. Confirm the rate for your specific code when you declare.
Regulations: efficiency and energy labels
- Minimum efficiency: Decision 14/2023/QD-TTg (effective 15/7/2023) does not allow the import of distribution transformers with efficiency below the minimum level under TCVN 8525:2015.
- Import inspection list: Decision 1725/QD-BCT of 01/7/2024 places three-phase distribution transformers with rated power from 25 kVA to 2,500 kVA, including dry-type transformers, on the list for energy efficiency checks and energy labeling. The list covers codes under 8504.21 and 8504.22.
- Energy label: Circular 52/2025/TT-BCT (effective 01/01/2026) keeps distribution transformers in the group of industrial equipment that must carry a mandatory energy label.
- Control, instrument and isolation transformers: these are outside the scope of “distribution transformers” above. State the function clearly on the declaration and keep the catalogue to support it.
- Explosion-proof transformers and quality in general: from 01/7/2026, imported goods are subject to risk-based quality management (Law 78/2025/QH15, Decree 37/2026/ND-CP). Check your machine’s code, especially explosion-proof models, against the MOIT’s list of medium- and high-risk goods in Circular 33/2026/TT-BCT.
- Used machines: Circular 56/2026/TT-BKHCN (effective 05/9/2026) applies to used machinery and equipment in Chapters 84 and 85 imported for production. As a rule, the equipment may not be older than 10 years, calculated as the import year minus the year of manufacture.
C/O and preferential duties
The biggest duty gaps are on 8504.22.11 (MFN 25%) and 8504.31.19 (MFN 20%). For goods from ASEAN, a Form D C/O brings the codes in the table to 0%. For goods from China, a Form E C/O brings most codes to 0%, except 8504.31.19 and 8504.33.19, which stay at 5%.
For details, see our guides to the Form E C/O, the AFTA agreement, CPTPP and VKFTA. If you import motors or generators with a project, see also our guide to importing electric motors into Vietnam.
Zlog tools for your shipment
Describe your goods in plain words and the Zlog HS Code assistant checks the Vietnamese tariff schedule and returns the HS code, duty rate and VAT with the legal basis. Zlog cross-checks the contract, invoice, packing list, bill of lading and C/O, and flags mismatches with suggested fixes.
5 steps to import transformers into Vietnam

Step 1: Identify the transformer type. Identify the type (distribution, control, instrument, explosion-proof), the dielectric type and the power, to choose the code and to know whether the unit is subject to the efficiency check.
Step 2: Check the test report. For distribution transformers, compare the factory test report with the minimum level in TCVN 8525:2015 before you pay. Contact the designated testing organization to confirm the procedure before the goods arrive.
Step 3: Prepare documents. The set includes the contract, commercial invoice, packing list, bill of lading, catalogue, drawings, a nameplate showing power, voltage, dielectric type and function, and the factory test report. Used machines need documents on the year of manufacture and an inspection certificate when requested; add a C/O if you want the agreement rate.
Step 4: File the declaration. File the declaration on VNACCS (Vietnam’s customs system), one line per model or power rating. The description states the machine type, function, rated power, voltage, dielectric type and condition of the goods.
Step 5: Clear customs and label. Pay duties and complete the inspection by risk channel and the sector-specific procedures, then clear customs. Apply the energy label (if the unit is in scope) and the Vietnamese secondary label before sale or connection.
Practical tips
State the function on the declaration
Keep descriptions and package counts consistent
Check the test report before you pay
Frequently asked questions (FAQ)
What does HS code 8504 cover?
8504 covers electrical transformers (power transformers and instrument transformers), static converters such as rectifiers, and inductors. Transformers are split into liquid dielectric and other types and by rated power.
What is the HS code for a 2,500 kVA transformer?
A liquid dielectric (oil-immersed) 2,500 kVA unit falls under subheading 8504.22 (over 650 kVA up to 10,000 kVA). A dry-type unit falls under 8504.34 (over 500 kVA). The 8-digit code also depends on the high-side voltage and function.
What is the HS code for a current transformer?
Current transformers and instrument transformers not exceeding 1 kVA fall under subheading 8504.31, the instrument transformer branch, split further by voltage. Higher-rated units move to subheadings 8504.32 onwards.
Do transformers need an energy label in Vietnam?
Three-phase distribution transformers from 25 kVA to 2,500 kVA, including dry-type, must meet minimum efficiency and carry an energy label. Control, instrument and isolation transformers are outside this scope.
What is the import duty on transformers in Vietnam?
The MFN rate on common codes is 5% to 25%, for example 5% for 8504.21.99 and 20% for 8504.31.19. With a Form D C/O these codes drop to 0%; with a Form E C/O most drop to 0%, but some stay at 5%. VAT for these codes is 10%.
Information checked in November 2026. Always confirm the HS code, duty rate and import rules for your specific goods against the regulations in force when you declare.