How to Import Hot and Cold Water Dispensers and Electric Water Heaters into Vietnam: HS Codes, Duties and Safety Rules

Importing hot and cold water dispensers, hot-and-cold water appliances and electric water heaters into Vietnam does not require an import license. The goods mostly fall under subheading 8516.10 with a 20% MFN duty, and they must meet the QCVN 4:2009/BKHCN electrical safety technical regulation.
This guide helps you identify which risk group your product belongs to so you can prepare the right file. The most important point: electric water heaters and electric hot-water dispensers (bình thủy điện) must pass state quality inspection at import, while drinking-water hot and cold dispensers only need a conformity declaration (công bố hợp quy) before sale.
SUMMARY: IMPORTING WATER DISPENSERS AND HEATERS INTO VIETNAM
- HS code: Water heaters and drinking-water hot and cold machines 8516.10.19; electric hot-water dispensers 8516.10.11.
- Import duty: MFN 20%; Form E 5%; Form D, CPTPP and EVFTA 0%.
- Quality inspection: Water heaters, electric hot-water dispensers and kettles are high-risk goods, with state inspection at import.
- Conformity declaration: Hot and cold water dispensers: declare conformity to QCVN 4:2009/BKHCN before the goods are placed on the market.
- Energy label: Storage water heaters must carry a mandatory label from 01/01/2026.

HS codes for water heaters and hot and cold water dispensers
Heading 8516 covers electric water heaters and domestic electrothermic appliances. Common codes:
| HS code | Description |
|---|---|
| 8516.10.11 | Electric hot-water dispenser (bình thủy điện), household type |
| 8516.10.19 | Electric instantaneous or storage water heaters, other: water heaters and drinking-water hot and cold machines |
| 8516.79.10 | Electric kettles |
| 8516.79.90 | Other electrothermic appliances |
| 8418.69.90 | Other refrigerating equipment; for drinking-water hot and cold machines with a chilling compartment for beverages |
| 8421.21.11 | Household water filters, including types with a water heating function |
Circular 36/2026/TT-BKHCN uses code 8516.10.19 for drinking-water hot and cold machines, 8418.69.90 for types with a beverage chilling compartment, and 8421.21.11 for filters with hot and cold functions (see also the guide to importing water purifiers). Solar water heaters that use no electricity fall under heading 8419; see the separate guide.
The correct code depends on the construction (whether there is a chilling tank or filter cartridge), power, voltage and intended use. The declarant is responsible for the code declared to customs.
Import duty and VAT
Import duty follows the Preferential Import Tariff attached to Decree 26/2023/ND-CP and its amendments. Rates looked up by HS code on 10/11/2026:
| HS code | MFN | ACFTA (Form E) | ATIGA (Form D) | VKFTA | CPTPP | EVFTA |
|---|---|---|---|---|---|---|
| 8516.10.11 | 20% | 5% | 0% | 20% | 0% | 0% |
| 8516.10.19 | 20% | 5% | 0% | 20% | 0% | 0% |
| 8516.79.10 | 25% | 0% | 0% | 0% | 0% | 0% |
| 8516.79.90 | 20% | 0% | 0% | 0% | 0% | 0% |
| 8418.69.90 | 10% | 0% | 0% | 0% | 0% | 0% |
For 8516.10.11 and 8516.10.19, a Form E C/O only brings the duty down to 5%, while Korean goods under VKFTA still pay 20% and the lookup site shows an AKFTA rate of 32%. ASEAN goods with Form D, and goods from CPTPP countries or the EU with valid documents, drop to 0%.
The standard VAT rate is 10%. Decree 174/2025/ND-CP reduces it to 8% from 01/7/2025 to the end of 31/12/2026 for goods not listed in Annexes I and II. The lookup site currently shows 8% for the 8516 codes and 10% for 8418.69.90, so check the rate for your specific code.
Regulatory requirements
Water heaters, electric hot-water dispensers and kettles: high risk
Annex I of Circular 36/2026/TT-BKHCN (signed 30/6/2026, effective 01/7/2026), item 4, applies to single-phase electrical equipment with a rated voltage of up to 250 V. This item covers instantaneous and storage water heaters for household use, code 8516.10.19, together with electric hot-water dispensers 8516.10.11 and electric kettles 8516.79.10. The requirements are:
- Electrical safety technical regulation QCVN 4:2009/BKHCN and Amendment 1:2016.
- Conformity declaration based on certification by a designated certification body, method 5 or 7 under Circular 14/2026/TT-BKHCN.
- Imported goods must go through state quality inspection.
Instantaneous water heaters also fall under Annex II, item 9.1 on electromagnetic compatibility (QCVN 9:2012/BKHCN and Amendment 1:2018). Item 9.1 states that it does not include hot and cold dispensers and other water heaters.
Hot and cold water dispensers: medium risk
Annex II, item 8.4 covers household drinking-water heating equipment, with or without a filtering or chilling function, codes 8516.10.19, 8421.21.11 and 8418.69.90. You make the conformity declaration to QCVN 4:2009/BKHCN based on certification or self-assessment results (method 1, 5 or 7) before the goods are placed on the market, with no state inspection registration at import.
Efficiency and energy labels
- Circular 52/2025/TT-BCT (effective 01/01/2026) makes energy labels mandatory for storage water heaters. Instantaneous water heaters, hot and cold dispensers and kettles are not on the list.
- Decision 14/2023/QD-TTg bans the import of equipment below the minimum efficiency level; storage water heaters are subject to TCVN 7898:2018 from 01/4/2025.
Three-phase equipment and used goods
The electrical safety items of Circular 36/2026/TT-BKHCN do not cover equipment using three-phase power, so high-capacity water heaters need to be checked separately by code. From 05/9/2026, Decree 292/2026/ND-CP replaces Decree 69/2018/ND-CP; Annex I of Circular 48/2026/TT-BCT bans the import of used goods of heading 85.16, except 8516.40.10, 8516.80 and 8516.90.
C/O and tariff preferences
The 20% MFN duty on subheading 8516.10 makes a C/O worthwhile.
ASEAN goods use a Form D C/O under ATIGA, and goods from CPTPP countries use CPTPP documents to reach 0%. Chinese goods use a Form E C/O and pay 5%. Korean goods get almost no reduction on water heaters, because the VKFTA rate equals MFN.
Check that the HS code, description and quantity on the C/O match the invoice before the goods arrive, to avoid the preference being refused.
Zlog tools for your shipment
Describe your goods in plain words and the Zlog HS Code assistant checks the Vietnamese tariff schedule and returns the HS code, duty rate and VAT with the legal basis. Upload the invoice, packing list and bill of lading; Zlog splits the line items, suggests HS codes, estimates duties and exports an Excel file for ECUS.
5 steps to import water dispensers and heaters into Vietnam

Step 1: Identify the type and HS code. Determine whether the product is a water heater, an electric hot-water dispenser or a hot and cold water dispenser, which tells you whether it falls under Annex I or II of Circular 36/2026/TT-BKHCN. The catalogue should state the heating type, capacity, power, voltage and whether there is a chilling compartment or filter cartridge.
Step 2: Conformity and quality inspection. High-risk goods register for state inspection and obtain a QCVN 4:2009/BKHCN conformity certificate from a designated body. Instantaneous water heaters also need QCVN 9:2012/BKHCN testing.
Step 3: File the declaration. File the declaration with the contract, invoice, packing list, bill of lading and C/O if available, stating the model, voltage, power, household use and new condition clearly.
Step 4: Pay duty, clear customs. Pay duty and complete customs clearance; high-risk goods need the quality inspection result as directed by the inspection body.
Step 5: Label before sale. Make the conformity declaration, affix the energy label for storage heaters, apply the conformity mark and the Vietnamese secondary label before sale.
Practical tips
Tell dispensers apart from water heaters
Korean goods get little duty relief
Prepare the energy label early
Frequently asked questions (FAQ)
What is needed to import hot and cold water dispensers into Vietnam?
Drinking-water hot and cold dispensers fall under Annex II, item 8.4 of Circular 36/2026/TT-BKHCN and need a conformity declaration to QCVN 4:2009/BKHCN before sale. They need no state inspection registration at import and are not on the energy label list.
Which technical regulation applies to hot and cold water dispensers?
Electrical safety testing under QCVN 4:2009/BKHCN and Amendment 1:2016. Results can come from an accredited or designated certification body, or from self-assessment under method 1, 5 or 7.
What should I know when importing storage water heaters into Vietnam?
Household storage water heaters are high-risk goods and need a QCVN 4:2009/BKHCN conformity certificate and state quality inspection. They must also meet the minimum efficiency level under TCVN 7898:2018 and carry the mandatory energy label from 01/01/2026.
How does the procedure for instantaneous water heaters differ?
Instantaneous water heaters are also high-risk goods for electrical safety and go through state inspection at import. You also need an electromagnetic compatibility conformity declaration to QCVN 9:2012/BKHCN; this type is not on the energy label list of Circular 52/2025/TT-BCT.
What is the import duty on hot and cold water dispensers in Vietnam?
For code 8516.10.19 the MFN duty is 20%, Form E 5%, and Form D, CPTPP and EVFTA 0%. The type with a chilling compartment, 8418.69.90, has an MFN rate of 10%.
Information checked in November 2026. Always confirm the HS code, duty rate and import rules for your specific goods against the regulations in force when you declare.
HS CODE ADVICE GROUP ON ZALO